This pull request solves the issue described in #221.

Negative temperature values from a DHT22 sensor can be interpreted as a 16 bit signed integer (short). There is no additional differentiation needed.

float DHT::readTemperature(bool S, bool force) {
  float f = NAN;
  short s = 0;
...
    case DHT22:
      s = ((short) data[2]) << 8 | data[3];
      f = s * 0.1;
      if (S) {
        f = convertCtoF(f);
      }
      break;
... 

The patch was successfully tested using five different DHT22 sensors on an Arduino UNO and an ESP8266 at positive and negative temperatures.

…hat negative temperature values are handled correctly
@dhalbert dhalbert requested a review from caternuson December 29, 2024 17:43
@bkormann80
Copy link
Author

Is any information missing?

@caternuson
Copy link

Negative temperature values from a DHT22 sensor can be interpreted as a 16 bit signed integer (short).

Are you sure about this? This doesn't look like twos complement, looks like sign/magnitude:

image

ex:

#include <stdio.h>
#include <stdint.h>

uint8_t  b2 = 0b10000000;
uint8_t  b3 = 0b01100101;

short t;

int main() {
  t  = ((short) b2) << 8 | b3;
  printf("t = %d\n", t);
  return 0;
}

yields:

t = -32667

Can you dump the actual bytes you are getting from whatever sensor you are using when there is a negative temperature?

@bkormann80
Copy link
Author

I am sure. In issue #221 I described this mismatch between documentation and all of my sensors. Documentation doesn't describe two complement, but sensor returns data this way.